Software:Article Title: Effects of robot assisted mirror therapy on motor function and cortical activation in patients with right hemisphere damage
Article Snippet: .. The fNIRS data were preprocessed and analyzed with fNIRS system data processing software (LIGHTNIRS, Shimadzu Corporation, Japan, Available from: https://www.shimadzu.com.cn/an/products/software-informatics/labsolutions-series/labsolutions-ir/index.html ) as follows: (1) Channels with significant motor artifacts were discarded, and the signals from the left and right brain regions (10 channels on each side) were superimposed and averaged separately. (2) Filter: The signal was passed through a bandpass filter with a frequency band of 0.01–0.08 Hz to remove significant periodic noise components, including heart rate noise (1 Hz), respiration (0.2–0.3 Hz), Meyer wave noise (0.1 Hz), and very low-frequency physiologic fluctuation noise (< 0.01 Hz). (3) Task-based averaging: Relative changes in oxyhemoglobin (Oxy-Hb) concentration were block-averaged (5 blocks × 15–30–15 s trial units). (4) Smoothing and baseline correction: Data were processed with Savitzky–Golay smoothing (window = 5, passes = 1) followed by baseline subtraction using two intervals (-15–0 s and 30–45 s). (5) The centroid value (CV) and integral value (IV) were calculated on the basis of the changes in Oxy-Hb levels. ..
Concentration Assay:Article Title: Effects of robot assisted mirror therapy on motor function and cortical activation in patients with right hemisphere damage
Article Snippet: .. The fNIRS data were preprocessed and analyzed with fNIRS system data processing software (LIGHTNIRS, Shimadzu Corporation, Japan, Available from: https://www.shimadzu.com.cn/an/products/software-informatics/labsolutions-series/labsolutions-ir/index.html ) as follows: (1) Channels with significant motor artifacts were discarded, and the signals from the left and right brain regions (10 channels on each side) were superimposed and averaged separately. (2) Filter: The signal was passed through a bandpass filter with a frequency band of 0.01–0.08 Hz to remove significant periodic noise components, including heart rate noise (1 Hz), respiration (0.2–0.3 Hz), Meyer wave noise (0.1 Hz), and very low-frequency physiologic fluctuation noise (< 0.01 Hz). (3) Task-based averaging: Relative changes in oxyhemoglobin (Oxy-Hb) concentration were block-averaged (5 blocks × 15–30–15 s trial units). (4) Smoothing and baseline correction: Data were processed with Savitzky–Golay smoothing (window = 5, passes = 1) followed by baseline subtraction using two intervals (-15–0 s and 30–45 s). (5) The centroid value (CV) and integral value (IV) were calculated on the basis of the changes in Oxy-Hb levels. ..
Blocking Assay:Article Title: Effects of robot assisted mirror therapy on motor function and cortical activation in patients with right hemisphere damage
Article Snippet: .. The fNIRS data were preprocessed and analyzed with fNIRS system data processing software (LIGHTNIRS, Shimadzu Corporation, Japan, Available from: https://www.shimadzu.com.cn/an/products/software-informatics/labsolutions-series/labsolutions-ir/index.html ) as follows: (1) Channels with significant motor artifacts were discarded, and the signals from the left and right brain regions (10 channels on each side) were superimposed and averaged separately. (2) Filter: The signal was passed through a bandpass filter with a frequency band of 0.01–0.08 Hz to remove significant periodic noise components, including heart rate noise (1 Hz), respiration (0.2–0.3 Hz), Meyer wave noise (0.1 Hz), and very low-frequency physiologic fluctuation noise (< 0.01 Hz). (3) Task-based averaging: Relative changes in oxyhemoglobin (Oxy-Hb) concentration were block-averaged (5 blocks × 15–30–15 s trial units). (4) Smoothing and baseline correction: Data were processed with Savitzky–Golay smoothing (window = 5, passes = 1) followed by baseline subtraction using two intervals (-15–0 s and 30–45 s). (5) The centroid value (CV) and integral value (IV) were calculated on the basis of the changes in Oxy-Hb levels. ..
|